Skip to main content
MVG Power Solutions Logo
Resin Cast Ring Current Transformer - LTCT Class 1.0 & 0.5 Accuracy 100% Factory Routine Tested

600/5A Ring Resin Cast Current Transformer | Low Tension Current Transformer (LTCT) | Ring Resin Cast LTCT

SKU / Model No.: 110*110-R-70
600/5A ring type resin cast low tension CT with 65mm round window, Class 1.0 / 0.5 and 5A secondary. Minimum order 3 pieces. Made in Delhi and dispatched across India.
Price on Request
Request Quote on WhatsApp (opens in new tab) Download Product Catalogue (PDF) — Resin Cast Ring Current Transformer - LTCT catalogue, opens in new tab View Product on IndiaMART TrustSEAL (opens in new tab)
Direct Manufacturer 100% Genuine Quality
IndiaMART TrustSEALCertified Star Seller ↗
(opens in new tab)
Fast Shipping Dispatched in 24 Hours
GST Invoice Input Credit Eligible
Electrical & Mechanical Parameters
Electrical Parameters
Electrical parameters of the 600/5A LTCT
Current Ratio 600/5A
Rated Primary Current 600A
Rated Secondary Current 5A
Accuracy Class Class 1.0 / Class 0.5 (0.5S on request)
Rated Burden 5 VA / 10 VA / 15 VA
Rated Frequency 50 Hz
Highest System Voltage 0.72 kV
Power Frequency Withstand 3 kV for 1 minute
Insulation Class Class E
Application Metering & current measurement
Mechanical Parameters
Mechanical parameters of the 600/5A LTCT
Construction Ring type, resin cast (low tension)
Inner Diameter (ID) 65 mm, round
Outer Diameter (OD) 105 mm
Width 35 mm (5 VA) / 35 mm (10 VA) / 45 mm (15 VA)
Body Material High-grade insulating cast resin
Terminal Cover Transparent cover over secondary terminals
Polarity Marking P1 / P2 primary, S1 / S2 secondary
Cooling Dry type, air cooled
Mounting Panel or busbar; cable or busbar passes through the centre hole
Model No. 110*110-R-70

600/5A LTCT (65mm): Low Tension Current Transformer Specifications and Uses

The 600/5A LTCT is a ring type resin cast low tension current transformer, also known as a low voltage current transformer or CT coil. It steps a primary current of 600A down to a 5A secondary signal (120:1) for LTCT energy meters, ammeters, multifunction meters, power analysers and protection relays. A balanced three-phase load of 600A at 415V is about 431 kVA, so this rating suits LT circuits up to that size. It is offered in Class 1.0 and Class 0.5 (0.5S on request) at 5, 10 or 15 VA, with a 65mm round window.

Resin Cast Construction and 65mm Round Window

This resin cast ring type current transformer has its winding and core fully cast in high-grade insulating resin, giving a solid, moisture-resistant body that holds its shape in hot, dusty panels. The ring measures 65mm inside and 105mm outside, and its width depends on the burden: 35 mm (5 VA), 35 mm (10 VA), 45 mm (15 VA). The primary cable or busbar simply passes through the centre hole, and a transparent cover protects the S1-S2 secondary terminals.

Where a 600/5A LTCT Is Used

At 600A, this LTCT is commonly specified for main LT incomers on the low-voltage side of distribution transformers, PCC panels, busbar trunking take-offs and large industrial feeders. Electrical contractors, panel builders and switchgear OEMs choose the resin cast LTCT when they need a robust metering CT that installs without opening the primary circuit.

Accuracy Class, Burden and Testing

Choose Class 1.0 for general panel metering or Class 0.5 for billing and check metering. Keep the total load of the meter and connecting leads within the selected burden (5, 10 or 15 VA) to hold accuracy. The CT is rated for 0.72 kV highest system voltage with a 3 kV, 1-minute power-frequency withstand, Class E insulation and 50 Hz operation. Every unit is routine tested for ratio error, phase displacement, insulation resistance and polarity (P1-P2, S1-S2) before dispatch.

How to Order

Mention the ratio, inner diameter, accuracy class and VA burden when you order. The minimum order is 3 pieces, and we dispatch from Mangol Puri, New Delhi across India with a GST invoice. Not sure about the rating? Compare the 500/5A LTCT or 800/5A LTCT, see the full Resin Cast Ring LTCT range, or read our CT ratio selection guide and CT burden calculation guide. Download the LTCT product catalogue (PDF) (opens in new tab) for the full model range and dimensions.

Frequently Asked Questions

What does a 600/5A LTCT ratio mean?

A 600/5A low tension current transformer reduces a primary current of 600A to 5A on the secondary, a ratio of 120:1. Set the energy meter or relay CT ratio to 600/5 so it shows the true line current.

Which load suits a 600/5A LTCT?

Choose it for circuits whose maximum running current is up to about 600A. On a 415V three-phase supply that is roughly 431 kVA. If the circuit normally runs well below that, a 500/5A LTCT gives better meter resolution; if it can exceed it, step up to 800/5A.

Should I choose Class 1.0 or Class 0.5?

Class 1.0 suits general panel metering and monitoring. Choose Class 0.5 for billing, check metering or energy audits where tighter accuracy is needed. Class 0.5S is available on request. Both classes are offered at 5, 10 and 15 VA.

What cable or busbar fits the 65mm window?

The 65mm round centre hole takes insulated cable or a round conductor up to 65mm overall diameter. For a flat busbar, check that its diagonal (with any sleeve) fits inside the opening, or send us the busbar size and we will confirm.

What is an LTCT and how do I get a price?

LTCT stands for Low Tension Current Transformer, also called a low voltage current transformer: a CT used on LT (up to 0.72 kV system voltage) circuits to feed meters and relays. Prices are on request: use the Request Quote button or WhatsApp +91 78360 04040 with the ratio, class, burden and quantity (minimum order 3 pieces).

5 Stars
11
4 Stars
1
3 Stars
0
2 Stars
0
1 Star
0

Share Your Experience

Have you used our Current Transformers? Leave a verified review on Google.

RK
Switchgear Fabricator, Noida
3 weeks ago

Consistent ratio accuracy across all batches of CTs. Their busbar mounting brackets fit standard MCC panels without any fabrication adjustments. Excellent dispatch speed.

VM
Panel Builder, Haryana
2 weeks ago

Best CT supplier in Delhi NCR. Polycarbonate casing is sturdy and terminal covers seal perfectly. GST invoice provided promptly with input tax credit.

AS
Electrical Contractor, Delhi NCR
1 month ago

We have been procuring ring CTs and tape-wound transformers from MVG Mangol Puri unit for over 3 years. Routine test reports are always provided with each lot.

SV
Power Systems Engineer, Ghaziabad
1 month ago

Accurate Class 1.0 metering accuracy and great mechanical endurance. Tested with secondary injection test kit and ratio errors were well within specified limits.

Price on Request